1–2 kW rated, enclosed housing
Start with VM1500i-VA/VB (1 kW rated, 1.1 kW maximum) or VM2500i-VA/VB (2 kW rated, 2.2 kW maximum). Both catalogue entries list recoil start. Confirm the VA or VB housing.
VEHEMENT model comparison
All 14 inverter catalogue entries in one place. Compare rated output, maximum output, electrical configurations, starting systems and listed weights.
Current catalogue
Open-frame inverter models cover 3–12 kW rated output. Enclosed VA/VB models cover 1–4 kW. Each enclosed entry groups two housing versions.
Showing all 14 catalogue entries.
| Model / details | Housing | Rated kW | Max. kW | Voltage / frequency | Starting system | N.W. / G.W. |
|---|---|---|---|---|---|---|
| VM3500IO | Open frame | 3 | 4 | 220 V or 230 V; 50 Hz or 60 Hz; catalogue also lists 120 V / 60 Hz | Recoil standard; electric / remote optional | To be confirmed |
| VM4500IO | Open frame | 4 | 5 | 220 V or 230 V; 50 Hz or 60 Hz; catalogue also lists 120 V / 60 Hz | Recoil standard; electric / remote optional | To be confirmed |
| VM5500 | Open frame | 5 | 5.5 | 220 V or 230 V; 50 Hz or 60 Hz; catalogue also lists 120 V / 60 Hz | Recoil standard; electric / remote optional | To be confirmed |
| VM6000IO | Open frame | 6 | 6.5 | 220 V or 230 V; 50 Hz or 60 Hz; 230/400 V equal-power three-phase option | Recoil standard; electric / remote optional | To be confirmed |
| VM7000IO | Open frame | 7 | 7.5 | 220 V or 230 V; 50 Hz or 60 Hz; 230/400 V equal-power three-phase option | Recoil standard; electric / remote optional | To be confirmed |
| VM8000IO | Open frame | 8 | 8.5 | 220 V or 230 V; 50 Hz or 60 Hz; 230/400 V equal-power three-phase option | Recoil standard; electric / remote optional | To be confirmed |
| VM10000I-OPEN | Open frame | 9 | 9.5 | 220 V or 230 V; 50 Hz or 60 Hz; 230/400 V equal-power three-phase option | Recoil standard; electric / remote optional | To be confirmed |
| VM12000I-OPEN | Open frame | 10 | 10.5 | 220 V or 230 V; 50 Hz or 60 Hz; 230/400 V equal-power three-phase option | Recoil standard; electric / remote optional | To be confirmed |
| VM13000I-OPEN | Open frame | 11 | 11.5 | 220 V or 230 V; 50 Hz or 60 Hz; 230/400 V equal-power three-phase option | Recoil standard; electric / remote optional | To be confirmed |
| VM14000I-OPEN | Open frame | 12 | 12.5 | 220 V or 230 V; 50 Hz or 60 Hz; 230/400 V equal-power three-phase option | Recoil standard; electric / remote optional | To be confirmed |
| VM1500i-VA/VB | Enclosed VA/VB | 1 | 1.1 | 220 V or 230 V; 50 Hz or 60 Hz; catalogue also lists 110 V / 60 Hz | Recoil standard; electric / remote optional | 14/16 kg* |
| VM2500i-VA/VB | Enclosed VA/VB | 2 | 2.2 | 220 V or 230 V; 50 Hz or 60 Hz; catalogue also lists 110 V / 60 Hz | Recoil standard; electric / remote optional | 21/23 kg* |
| VM4000i-VA/VB | Enclosed VA/VB | 3 | 3.3 | 220 V or 230 V; 50 Hz or 60 Hz; catalogue also lists 110 V / 60 Hz | Recoil standard; electric / remote optional | 22/24 kg* |
| VM6000i-VA/VB | Enclosed VA/VB | 4 | 4.5 | 220 V or 230 V; 50 Hz or 60 Hz; catalogue also lists 110 V / 60 Hz | Recoil standard; electric / remote optional | 23/25 kg* |
No catalogue entries match both filters. Change the housing or rated output, or reset the filters to see the full range.
* N.W. / G.W. means net weight / gross weight. Enclosed values are for the recoil-start version and are the same for VA and VB. VA/VB differ only in housing; their other technical specifications are the same. Optional equipment can change final weight. “To be confirmed” means the catalogue does not provide a value.
The basic configuration is single-phase with recoil starting. Where listed, 230/400 V is the equal-power three-phase alternator option, with the same rated output in single-phase and three-phase operation. Electrical values are order configuration choices; confirm the required combination before ordering.
The base configuration is single-phase with recoil starting and basic panel sockets. Inverter generators also include an ECO switch and indicator lights.
Electric starting and remote starting are available across the model range. Electric-start versions retain recoil starting. USB outlets, VFT meters (voltage, frequency and running time), ATS, one-touch starting and pull handles are optional; specify the required equipment and combination in your enquiry.
For some volume orders, selected options such as USB or a VFT meter may be included at no extra charge. Inclusion and pricing are confirmed in the quotation.
220 V or 230 V and 50 Hz or 60 Hz can be specified for the customer. These are order configuration choices, not a statement that every machine switches between them. Where listed, 230/400 V identifies the equal-power three-phase alternator option: single-phase and three-phase operation have the same rated output in that configuration. Confirm the selected output, sockets and phase arrangement in the order specification.
Our public download is the product catalogue. Final specifications, manuals and even the customer model name depend on the agreed configuration. Use the catalogue model as a starting point, then confirm the order-specific parameters and documentation with us.
All dimensions below are L × W × H in millimetres. Carton dimensions are the machine dimensions plus 15 mm in each direction. Confirm the packing for the final ordered configuration.
| Model | Machine (mm) | Carton (mm) |
|---|---|---|
| VM1500i-VA/VB | VA 430 × 270 × 400 mm; VB 480 × 280 × 430 mm | VA 445 × 285 × 415 mm; VB 495 × 295 × 445 mm |
| VM2500i-VA/VB | VA 470 × 285 × 450 mm; VB 520 × 290 × 470 mm | VA 485 × 300 × 465 mm; VB 535 × 305 × 485 mm |
| VM4000i-VA/VB | VA 515 × 320 × 495 mm; VB 500 × 300 × 470 mm | VA 530 × 335 × 510 mm; VB 515 × 315 × 485 mm |
| VM6000i-VA/VB | VA 515 × 320 × 495 mm; VB 500 × 300 × 470 mm | VA 530 × 335 × 510 mm; VB 515 × 315 × 485 mm |
A practical starting point
| Specification | VM4500IO | VM6000i-VA/VB |
|---|---|---|
| Housing | Open frame | Enclosed VA/VB |
| Rated output | 4 kW | 4 kW |
| Maximum output | 5 kW | 4.5 kW |
| Voltage / frequency | 220 V or 230 V; 50 Hz or 60 Hz; catalogue also lists 120 V / 60 Hz | 220 V or 230 V; 50 Hz or 60 Hz; catalogue also lists 110 V / 60 Hz |
| Starting system | Recoil standard; electric / remote optional | Recoil standard; electric / remote optional |
| Fuel tank | 10L | 7L |
| N.W. / G.W. (recoil) | To be confirmed | 23/25 kg* |
| Machine L × W × H | To be confirmed | VA 515 × 320 × 495 mm; VB 500 × 300 × 470 mm |
| Carton L × W × H | To be confirmed | VA 530 × 335 × 510 mm; VB 515 × 315 × 485 mm |
Both catalogue entries list 4 kW rated output. The VM4500IO lists 5 kW maximum output, while the VM6000i-VA/VB lists 4.5 kW maximum output. Compare the rated figures first; a higher maximum figure is not a higher continuous-output rating.
Both have recoil starting as standard, with electric and remote starting optional. The two fuel-tank sizes do not establish a runtime comparison. Request comparable noise, runtime and output-quality test data before choosing on those criteria.
* N.W. / G.W. means net weight / gross weight. Enclosed weights apply to the recoil-start version and are the same for VA and VB. VA/VB differ only in housing; their other technical specifications are the same. Optional equipment can change the final weight. Open-frame weights are not yet listed. Carton dimensions add 15 mm to each machine dimension.
Choose by requirement
Start with VM1500i-VA/VB (1 kW rated, 1.1 kW maximum) or VM2500i-VA/VB (2 kW rated, 2.2 kW maximum). Both catalogue entries list recoil start. Confirm the VA or VB housing.
Compare VM3500IO with VM4000i-VA/VB at 3 kW rated. At 4 kW rated, compare VM4500IO with VM6000i-VA/VB. Check electrical and start configurations before selecting a housing.
VM5500 lists 5 kW rated output. The 6–12 kW rated options are VM6000IO (6 kW), VM7000IO (7 kW), VM8000IO (8 kW), VM10000I-OPEN (9 kW), VM12000I-OPEN (10 kW), VM13000I-OPEN (11 kW), VM14000I-OPEN (12 kW). The current enclosed catalogue stops at 4 kW rated.
Choose the base model and required electrical output first. Then define colour, labels, panel and packing requirements. More specialised features need a platform-specific review.
Explore real OEM customization workVM6000i-VA/VB is rated at 4 kW; VM14000I-OPEN is rated at 12 kW. The digits in a model name are not its rated power. Keep both rated and maximum output in your enquiry and request the operating conditions and permitted maximum-output duration.
Share the equipment you intend to power, including running and starting requirements. Rated power alone does not establish suitability for every load.
Include model names, destination market, voltage, frequency, phase, sockets, starting system and branding requirements.
MOQ, production lead time and warranty terms are agreed during quotation according to the model, configuration, order quantity and destination market.
Discuss your model requirements